This website uses local storage to ensure you get the best experience on our website.

Table of Contents

Table of Disabled Features per Calculation Type

Various simplifying assumptions are made in the steady calculations, as summarised in the table below. Note that the aerodynamic information” and “performance coefficients” calculations only model the rotor (at zero tilt angle), whereas the other steady calculations model the whole turbine.

Functionality Aerodynamic Information Performance Coefficient Steady Power Curve Steady Operational Loads Steady Parked Loads
Which structural components are included? Rotor only Rotor only Whole Turbine Whole Turbine Whole Turbine
Component flexibility? No Yes No Yes Yes
Wind direction other than 0 deg? No No No No No
Load varies with rotor azimuth? No No No Yes (azimuth=0) Yes
Turbine yaw included? No No No No Yes
Tilt included in rotor aerodynamics and structure? No No No Yes Yes
Wind shear included? No No No No Yes
Upflow included? No No No No Yes
Gravity load included? No No No No Yes
Tower Shadow included? No No No No Yes
Blade prebend and sweep included? No Yes Yes Yes Yes

Last updated 16-09-2024